Maintenance | Power & Energy Ballance Condenser Retube

Tubes in the existing condenser had thinned and had to be replaced.

Project included the following:

  • 1462 tubes, 23mmOD with 1mm wall.
  • Tubes Admiralty Brass to ASTM B 111
  • Tube plates kept in position while old tubes were removed.
  • Measured holes to calculate the expansion required.
  • Expanded tubes to desired wall thinning.
  • Cut and trimmed the tube ends to be flush with the tube plate.
  • Refurbished water box and reassembled pressure side of condenser.